Sign In | Join Free | My webtextiles.com |
|
Brand Name : Envsin
Model Number : ECS7100-15
Certification : CE and ISO
Place of Origin : China
MOQ : 1
Price : To Be Negotiated
Payment Terms : L/C, T/T, Western Union
Supply Ability : 25 per month
Delivery Time : 30-35 business days after received the payment
Packaging Details : Wooden packing
Product name : 990L Climatic Chamber
key word : Ess Climatic Chamber
Item Name : Temperature Cycling Climatic Chamber
Test Space : 990L
Internal size : 1100*950*950mm (W*D*H)
External size : 1350mm*1890mm*2050mm (W×D×H)
990L Ess Climatic Chamber SUS304 Stainless steel Temperature Cycling Climatic Chamber
Designed for high and low temperature test and rapid temperature change ESS test for whole product, machine component, and materials.
Test Space | 990L | ||
Internal size | 1100*950*950mm (W×D×H) (W×D×H) | ||
External size | 1350mmx1890mmx2050mm(W×D×H) | ||
Power supply | AC380V±10%,50Hz±1,60A, 3/N/PE, earth resistance < 4Ω | ||
Max. Power | 75KW(The average power is about 35KW) | ||
Max. Currency | 130A(The average current is about 55A) | ||
Cooling Method | Water -Cooled(Cooling system) | ||
Installation Site |
| ||
Cooling Water | Water temperature: 5℃≤ water temp.s ≤28℃.If the source of water is air conditioning chilled water, it’s temp is lower than 10℃ ,need to take some measures preventing pipe condensing water. | 1.If adopt the design of the air cooling, do not need water.
2.If user need build new cooling water circulation system.Cooling tower standard ≥10tons, or Water chiller refrigerating capacity≥35KW(20℃).
3.Cooling water system :GB50050-1995 | |
Water flow:≥ 10 tons/hour | |||
Pipe diameter:G2.5 inch ×2 | |||
Inlet water pressure:0.3MPa~0.6MPa | |||
water pressure difference inlet and outlet:≥0.2MPa | |||
Water request: meet standard GB50050-1995 |
Temp Test | Temp.Range:-70℃~+180℃ | Note:1.Test with no load, meeting GB/T5170-2008,if no other special notice.
2.Ambient Temp 25℃, good ventilation condition: function well if 35℃≥RT>25℃;Cool down rate and thermal load capacity will be affected by ambient low temperature. |
Temp Fluctuation:±0.5℃ | ||
Temperature Uniformity:0.1℃~2.0℃ | ||
Temp Deviation :±0.1℃~±2.0℃ | ||
Temp Gradient:<2.0℃ | ||
Linear temperature change rate - within - 45 ~ + 100 ℃, 15 ℃ / min | ||
Nonlinear temperature change rate<15℃/ min | ||
Temp Humidity Test
| Temp.Range:+10℃~+95℃ | |
Humidity Range:10%RH~98%RH | ||
Temp. Uniformity:±0.5℃~±2.0℃ | ||
Humidity Uniformity:±1.0%RH~±5.0%RH | ||
Temp. Deviation:±0.1℃~±2.0℃ | ||
Humidity Deviation:±1.0%RH~±5.0%RH | ||
Temp. Fluctuation:±0.1℃~±0.5℃ | ||
Humidity Fluctuation:±1.0%RH~±3.0%RH | ||
Temp Gradient :<2.0℃ | ||
Humidity Gradient<5.0%RH | ||
Test Standards | 1 GB/T 2423.1 Low Temp. Test | 5 GJB 150.3 High Temp. Test |
2 GB/T 2423.2 High Temp. Test | 6 GJB 150.4 Low Temp. Test | |
3 GB/T2423.34 Climate Cycling Test | 7 GJB 150.9 Climate Test | |
4 IEC60068-2 Climate Test | 8 MIL-STD-202G-103BHumidity Test | |
Load Thermal Capacity Chart | Apply to standard temperature test, the thermal capacity for loading varies from different temperature value. | |
Temperature and Humidity Control Chart | ![]() |
1.Chamber door | 2.Observation window |
3.Control Pad | 4.Working Lights |
5.Cable port | 6.Extensional control pad |
7.Wheels | 8.Power distribution board |
![]() |
990L SUS304 Temperature Cycling ESS Test Chamber Images |