SAE-J1211 335L Stress Screening Environmental Test Chambers

  • 1
  • 2
  • 3

Brand Name : Envsin

Model Number : ETS6340S3

Certification : CE and ISO

Place of Origin : China

MOQ : 1

Price : To Be Negotiated

Payment Terms : L/C, T/T, Western Union

Supply Ability : 25 per month

Delivery Time : 30-35 business days after received the payment

Packaging Details : Wooden packing

Product name : Environmental Stress Screening Test Chambers

Test Space : 335L

Internal size : 800×650×650mm (W*D*H)

External size : 1800mmx2500mmx2300mm(W*D*H)

Power supply : AC380V±10%,50Hz±1 four wire three phase+ earth wire(3/N/PE),Earthing resistance<4Ω

Max. Power : 65KW

Max. Currency : 110A

Cooling Method : Water-Cooled

Contact Now

335L Environmental Stress Screening Test Chambers Water-Cooled Climatic Test Chamber

The chamber used to test samples of non-heat dissipation or low heat dissipation. For test specimen with heat dissipation, the heat dissipating power can not exceed the cooling capacity of refrigeration system, otherwise it will affect the chamber temperature conversion speed and capacity. It is proposed test sample’s heat is less than 300W.

Products Tech Specification(Feature):

Test Space

335L

Internal size

800*650*650mm(W×D×H)

External size

1800mm*2500mm*2300mm (W*D*H)

SAE-J1211 335L Stress Screening Environmental Test Chambers

Power supply

AC380V±10%,50Hz±1 four wire three phase+ earth wire(3/N/PE),Earthing resistance<4Ω

Max. Power

65KW

Max. Currency

110A

Cooling Method

Water-Cooled

System structure

Three part structure:immobile independent test area.Preheating area. Precooling area

Installation Site

  • No strong electromagnetic radiation source nearby
  • Close to drainage system ( within 2 meters to refrigeration unit,for condensate water)
  • The ground bearing capacity not less than 20000kg/m2
  • Prepare proper power supply and water supply
  • If need water or gas supply, should be equipped with in advance
  • Ambient Temp: 5℃~25℃suggested, 25℃~35℃ function well;(for air-cooled model);5℃~40℃ function well (for water-cooled model)
  • Ambient Humid:≤85%RH;
  • Ambient Pressure:86KPa~106KPa;
  • Installation space assurances, as following

SAE-J1211 335L Stress Screening Environmental Test Chambers

A:100cm

B:80cm

C:150cm

D:80cm

E:60cm

Cooling water

Water Temp:5℃≤Water Temp≤28℃ reach all technical index, 28℃<Water Temp≤33℃ function well(cooling time will change);

Water source Temp ≤10℃,need to prevent condensate water arise

1:If test chamber adopt air-cooled,no need cooling water

2: If user need build cooling cycle water system, cooling tower specification≥15 ton or condensing unit refrigerating capacity≥40KW(20℃)

3:Cooling water system should be GB50050-1995 industrial cycling cooling water treatment design regulation standard

Water flow:≥15 ton/h

Pipe diameter:G2.5 inches ×2

hydraulic pressure:0.3MPa~0.6MPa

Hydraulic Pressure Difference:≥0.2MPa

Water quality requirement:GB50050-1995

Air compression

Compressed air supply pressure:0.6MPa~0.7MPa

Humidity of compressed air under Pneumatic use:≤30g/m³

Humidity of compressed air under dry air use:≤1.5g/m³

Specifications:

Working chamber temp shock test parameter

Thermal Shock Test Chambers--S2:

  • Low-temp shock range:﹣55℃~﹣10℃
  • High-temp shock range:+60℃~+150℃

Low-High+Room Temperature Shock Test Chamber-S3:

  • Low-temp shock range:﹣65℃~﹣10℃
  • High-temp shock range: +60℃~+150℃
  • PAMP Environmental Stress Screening
  • Low Temp. Range:﹣55℃~﹣10℃
  • High Temp. Range: +60℃~+125℃
  • Temp. Gradient:3~30℃/min
  • Temp. Fluctuation:±0.1℃~±1.0℃
  • Temp. Uniformity:±0.5℃~±2.0℃
  • Temp Deviation:<±2℃

Note:

1.Testing with no load, meeting GB/T5170-2008, if no other special notice.

2.Temp. range in 0℃~+60℃, setting Shock temp. and RAMP Environmental Stress Screening function are disapprove.

3. Air cooled test chamber test data at Ambient Temp. 25℃, good ventilation condition;35℃≥RT>25℃ function well; low temp range, cooling rate and thermal load capacity will be affected by the changeable environment temperature.

4.Water cooled test chamber test data at water temp ≤28℃, Hydraulic pressure 0.3MPa~0.6Mpa, Hydraulic Pressure Difference≥0.2Mpa

Preheat temp.

Temp. SV: +50℃~+220℃

Temp rise time: RT→+220℃ 50min

Precool temp.

Temp. PV:﹣75℃~+70℃

Temp. reduction time: RT-75℃ 60min

Temp. recovery time

<15min(measure in air outlet)

Test standard

Experiment standard-S2:

GB/T2423.22

MIL STD 202F, method 107G

IEC 60068-2-14, Test Na

BS 2011

DIN 40046, Test Na

JESD22-A101-A

Experiment standard-S3:

GJB 150.5-1986

MIL STD 883H

MIL STD 202G

IEC 60068-2-14

JIS C 60068-2-14

JASO D 014–4

EIA JED-2531A

Environmental Stress Screening Test Standard:

IEC 60749-25(JESD22-A104D)

IEC 60068-2-14NB(JIS C0025NB)

IEC 61747-5(EIA JED-2531A)

JESD22-A105-B

IPC-9701

SAE-J1211

SAE-J1211 335L Stress Screening Environmental Test Chambers

1.Chamber door

2.Observation window

3. Control Pad

4. Preheat area

5. Working Lights

6. Cable port

7. Precooling area

8.Extensional control pad

9.Power distribution board

10.Refrigeration unit room

SAE-J1211 335L Stress Screening Environmental Test Chambers


Product Tags:

335L Environmental Test Chambers

      

SAE-J1211 Environmental Test Chambers

      

335L Climatic Test Chamber

      
Quality SAE-J1211 335L Stress Screening Environmental Test Chambers for sale

SAE-J1211 335L Stress Screening Environmental Test Chambers Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Envsin Instrument Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)